{"id":2791,"date":"2019-08-08T10:14:49","date_gmt":"2019-08-08T03:14:49","guid":{"rendered":"http:\/\/yourtech.vn\/?post_type=product&#038;p=2791"},"modified":"2019-10-08T13:55:07","modified_gmt":"2019-10-08T06:55:07","slug":"type-dw-distillation-unit","status":"publish","type":"product","link":"https:\/\/yourtech.vn\/en\/san-pham\/type-dw-distillation-unit\/","title":{"rendered":"TYPE DW Distillation Unit"},"content":{"rendered":"<div id=\"c3275\" class=\"csc-default\">\n<div class=\"csc-header csc-header-n2\">\n<h2 style=\"text-align: justify;\"><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">DW components<\/span><\/h2>\n<\/div>\n<div class=\"csc-textpic-text\" style=\"text-align: justify;\">\n<ul>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Cylindrical, vacuum-tight distillation boiler, pressure relief valve, hinged lid counterbalanced by a gas spring, viewing glass, temperature- and solvent-resistant gasket<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Heating jacket with thermal oil as heat transfer medium, integrated Ex-de heating elements, minimum-level switch as safety against low oil level<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Insulation of boiler, heating jacket, and lid<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Water-cooled condenser, parts in contact with solvent are made of stainless steel<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Temperature limiter switches off the heating if the solvent temperature exceeds a set limit<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Cleaning hole with hinged cover for residue discharge<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Signal lamp and EMERGENCY STOP, explosion-proof, mounted directly at the distillation unit<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Control cabinet with control elements for installation outside the hazardous area<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Separate control box for the pneumatic system<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Batch distillation<\/span><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div id=\"c3268\" class=\"csc-default\">\n<div class=\"csc-header csc-header-n3\" style=\"text-align: justify;\">\n<h2><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Accessories<\/span><\/h2>\n<\/div>\n<div class=\"csc-textpic-text\">\n<ul style=\"text-align: justify;\">\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Vacuum unit<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Automatic filling in connection with vacuum<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">Thermostatic valves if the unit is connected to an on-site cooling\/public water supply; cooling water devices with separate circuits are also available<\/span><\/li>\n<li><span style=\"font-size: 20px; font-family: 'times new roman', times, serif;\">For the distillation of wash solvents: compact version for installation outside the hazardous area.<\/span><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3321\" src=\"http:\/\/yourtech.vn\/wp-content\/uploads\/2019\/08\/maychungcatdungmoitypeDW1-1.jpg\" alt=\"\" width=\"766\" height=\"425\" srcset=\"https:\/\/yourtech.vn\/wp-content\/uploads\/2019\/08\/maychungcatdungmoitypeDW1-1.jpg 766w, https:\/\/yourtech.vn\/wp-content\/uploads\/2019\/08\/maychungcatdungmoitypeDW1-1-510x283.jpg 510w, https:\/\/yourtech.vn\/wp-content\/uploads\/2019\/08\/maychungcatdungmoitypeDW1-1-650x361.jpg 650w\" sizes=\"auto, (max-width: 766px) 100vw, 766px\" \/><\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>DW components Cylindrical, vacuum-tight distillation boiler, pressure relief valve, hinged lid counterbalanced by a gas spring, viewing glass, temperature- and solvent-resistant gasket Heating jacket with thermal oil as heat transfer medium, integrated Ex-de heating elements, minimum-level switch as safety against low oil level Insulation of boiler, heating jacket, and lid Water-cooled condenser, parts in contact&#8230;<\/p>\n","protected":false},"featured_media":3322,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[362],"product_tag":[],"class_list":{"0":"post-2791","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-distillation-unit","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/yourtech.vn\/en\/wp-json\/wp\/v2\/product\/2791","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yourtech.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yourtech.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/yourtech.vn\/en\/wp-json\/wp\/v2\/comments?post=2791"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yourtech.vn\/en\/wp-json\/wp\/v2\/media\/3322"}],"wp:attachment":[{"href":"https:\/\/yourtech.vn\/en\/wp-json\/wp\/v2\/media?parent=2791"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yourtech.vn\/en\/wp-json\/wp\/v2\/product_brand?post=2791"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yourtech.vn\/en\/wp-json\/wp\/v2\/product_cat?post=2791"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yourtech.vn\/en\/wp-json\/wp\/v2\/product_tag?post=2791"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}